4) Check that dimension D is greater than or equal to 435 mm.
There must be no obstacles to impede the movement of the arm in
this area.
5) Check that dimension L is between 800 mm and 2,000 mm.
If L < 1250, the installation of a set of photoelectric cells is essential.
65 mm
175 mm
455 mm
355 mm
6)
Trace a horizontal axis
AH
in the middle of the reinforcement, perpen-
dicular to the rotational axis of the gate.
If the gate has no reinforcements, place the motors approximately
1/3 of the way up the gate leaves from the bottom.
Extend this line on the pillar until it intersects with
AM
.
7)
Place the template where the 2 lines intersect and drill.
5. MOUNTING AND SECURING THE MO
TORS
1)
Open the upper cover using the specific key supplied.
2)
Unscrew the 2 bolts of the lower cover and remove.
3)
Secure the motor, checking the level.
4)
Assemble:
• the motor arm on the motor using an HM screw 10 x 40 (
16
)
• the leaf arm on the engine arm using the short sha (
21
)
• Note: the gate arm can be fitted both ways.
• the leaf bracket on the leaf arm using a damper (
24
), 2 rings (
23
)
and a long sha (
22
).
5)
Unlock the motor arms using the button located on top of the motor.
: arms locked
: manual operation
In the unlocked position, move the arms slowly to avoid dam-
aging the motors.
5
Copyright© 2017 SOMFY ACTIVITES SA. All rights reserved.
EN
Axovia 220B