DMS-1200 Release 6 Operations Manual
Section 8 – System Commissioning with EasySet
89
ROU / RDU
Fields
User Configuration
SOLiD
Recommendation
TX Output
ALC / Level
On/Off toggle for Auto Limit Control. When On, system
will apply attenuation when this value is met or
exceeded.
Turn On. Set to max
power output for that
band (according to
FCC rating).
TX Output
AGS Level
On/Off toggle for Auto Gain Setting. When On, the
system sets the output power to the predetermined
power level automatically.
Set to same value as
ALC level.
SD Level
The system shuts down when power output reaches
the value in this field.
Set to 2dBm above Tx
Output ALC level.
Power High
High power limit used in Alarm function.
Set to 1dBm below
the SD level
Power Low
Low power limit used in Alarm function.
Set to 0dBm
Rx Input ALC
/ Level
On/Off status of Auto Limit Control for input power.
Turn On. Set to -
50dBm.
Table 8.1 – EasySet Fields
5.
When you have finished setting each parameter, click
Run
to start the Auto Setup /
Commissioning process. Check status in the progress bar.
Once complete, the system generates a report with final results.
6.
Click
Clear
to reset or
Save
to download the report in spreadsheet format.