DMS-1200 Release 6 Operations Manual
Section 7 – DAS Device Control
66
7.5.3 MROU Setup
This section describes how to set up the mid-power remote unit (MROU).
1. In the Tree Menu or Menu bar, click on the MROU to configure.
In the MROU setup screens, some fields show current settings and are not user configurable.
Other fields allow you to configure parameters for the device. You can see the Min / Max values
for the parameter by clicking in the field.
2. Configure the
System Information
according to the guidelines in following table:
ROU Field
Action / Description
User
Configure
ROU Name
Enter a name to be used to Identify ROU throughout the system.
Maximum 40 alpha-numeric characters.
Y
F/W Version
Shows Firmware version of the ROU CPU.
N
Temperature
Shows current temperature of ROU and temperature alarm status.
Green = temp within limits. Red = temp above/below limits.
N
Temp Limit
Shows Low / High temp alarm settings.
N
Link Fail /
Reset
Shows status of BIU communication. Green = normal operation;
Red = link failure. Click
Reset
to in case of link failure.
Y
Fan Fail
Displays Fan status. Green = normal operation; Red = fan failure.
(If fan is not installed, this indicator is greyed.)
N
Door Open
Shows Door status: Green = normal. Red = Door open or door
switch has failed.
N
DC Fail
Shows DC Power status: Green = normal. Red = power supply
unit is experiencing over-current or low voltage conditions.
N
Backup /
Restore
Click
Backup
to save the current settings for the ROU/RDUs.
Click
Restore
to apply settings from backup file.
Y
Table 7.14 – MROU Control Screen Fields – System Information