F
ibre cabLeS
Fibre optic cabling will be required between the console processor(s) and each outboard I/O Unit – RIO, Alpha-link
LIVE-R, SDI-MADI and MORSE units all use duplex fibre for audio interfacing. Redundant systems will require two
individual fibre links to each outboard unit; see the examples on the following page.
The Alpha-Link 8-RMP microphone amplifiers do not require audio fibre connection to the console. They connect to a local
Alpha-Link LIVE-R unit using analogue and network cabling.
It is a sensible practice to install spare cable runs to allow for system expansion or to replace any leads that may subsequently
become damaged.
The table below details the connectors used to interface the individual I/O units.
F
IbRE
C
OnnECTORS
* MORSE units are fitted with multimode adapters as standard. Singlemode interfaces are available to special order only and
will have extended lead-times.
F
ibre
S
tanDarDS
The default fibre interface adaptors fitted are suitable for multimode fibre connections. RIO stageboxes and MORSE units
may optionally be ordered with singlemode versions for any of the fibre links. (The corresponding port on the console
processor must also be changed to singlemode.) Alpha-Link LIVE is only available with multimode interfaces.
All SSL fibre interfaces use flat (PC) termination not angled (APC).
Singlemode and multimode interfaces and connectors are almost identical in appearance, however, they are operationally
incompatible – the two different standards cannot be mixed for any individual link.
The table below lists the maximum cable lengths permissable for the fibre interface standards available.
F
IbRE
S
TAnDARD
M
AxIMuM
D
ISTAnCES
Data Type
Fibre Type
Specification
Maximum Length
note
MADI
Multimode
50/125um
550m
Default fitment
“
Multimode
62.5/125um
<300m
“
Singlemode
9/125um
2,000m
Source
Destination
Data Type
Connectors
Standard
C10 Console
Alpha-Link LIVE-R
MADI
LC – SC
Multimode only
C10 Console
RIO
MADI
LC – LC
Multimode or Singlemode
C10 Console
MORSE Router
MADI
LC – SC
Multimode or Singlemode*
C10 Console
MORSE Stagebox
MADI
LC – SC
Multimode or Singlemode*
MORSE Router
MORSE Stagebox
MADI
SC – SC
Multimode or Singlemode*
C10 Console
SDI – MADI box
MADI
LC – ST
Multimode only
Installation Cabling
C10 HD Installation Manual
Section 2: Preparation
|
Page 2-9
Summary of Contents for C10 HD
Page 16: ...Page 1 6 Section 1 Introduction C10 HD Installation Manual C10 HD Introduction ...
Page 77: ...Installation C10 HD Installation Manual Section 3 Installation Page 3 27 ...
Page 78: ...Installation Page 3 28 Section 3 Installation C10 HD Installation Manual noteS ...
Page 119: ...C10 HD Installation Guide Section 4 Configuration Page 4 37 B Console Configuration ...
Page 120: ...Page 4 38 Section 4 Configuration C10 HD Installation Guide B Console Configuration ...
Page 218: ...Page 6 32 Section 6 Appendices C10 HD Installation Manual ...
Page 232: ...Specifications Page 7 10 Section 7 Service Information C10 HD Installation Manual ...