Measurements Menu
This displays the data retrieved from the inverter. Use the
↑↓
buttons to move up and down the list:
AC Energy
AC Power
AC Voltage
AC Current (3 phase average)
DC Voltage
Pressing ESC will take the screen back to the start menu.
Note: data will only be available when inverter is awake and communicating.
Set Inverter Menu
Displays inverter parameters, some of which may be modified with the keypad.
1.
Inverter ID
Serial port address/ID of the inverter
2.
Baud Rate
Serial port baud rate
(Currently not adjustable)
3.
Vac Very High
AC Voltage Critical High (Not adjustable)
4.
Vac High
AC Voltage High (Not adjustable)
5.
Vac Low
AC Voltage Low (Not adjustable)
6.
Vac Very Low
AC Voltage Critical Low (Not adjustable)
7.
Fac Low
AC Frequency Low (Not adjustable)
8.
Fac Very Low
AC Frequency Critical Low (Not adjustable)
9.
Fac High
AC Frequency High (Not adjustable)
Note: data is only available when inverter is awake and communicating.
Monitor Menu
Displays monitor settings that may be modified with the keypad.
1.
LAN
Local Area Network configuration, applicable only for
SolrenView monitoring
1. DHCP Mode
See SolrenView manual on DHCP
2. Static/Fallback IP
If DHCP is turned on, this is then used as the fallback
IP
3. Gateway IP
IP address of LAN’s default gateway.
4. Netmask
Subnet mask
2.
Date/Time
Manual time set. This may be overwritten by
scheduled NIST updates.
3.
Reboot
Reboots the monitor
4.
Remote SRV
This starts the transmit process necessary for
SolrenView monitoring. Units that are ordered with
SolrenView monitoring will have this field turned on.
Caution: Enabling this field when SolrenView service
has not been confirmed/authorized may result in
unnecessary wear on the unit.