SkyWay Series Multi-Point Operator’s Guide
39
The limited management scheme limits the bandwidth by measuring the total
throughput of a station; this entails measuring both the I-frames received and the I-
frames sent. The scheme runs with one-second cumulative windows, which are
leveled out over 5 second blocks. Starvation is avoided by using RNR's to throttle
the bandwidth of the hogging side.
Bandwidth management can be used to configure the amount of bandwidth that
each Sub station will be limited to. The bandwidth can only be configured using
the Base. All Subs can be configured at once or each Sub can be configured
individually.
Configuring Bandwidth Management
Base
1.
Go to the RF Bandwidth Management Configuration (1.2.3.5) screen
2.
Change the Bandwidth Management Mode to “Limited”
Subs - All Set Simultaneously
1.
Change the Default Bandwidth value to a desired amount
2.
Change the Set all Subs to Default field to “Yes”
3.
Type “.w”
Subs - Each Set Individually
1.
Go to the Station Bandwidth and change each value as desired.
2.
Type “.w”
Verifying Bandwidth Management Changes
Base
1.
On the Base unit, go to the RF Bandwidth Management Configuration
(1.2.3.5) screen and verify all Subs have changed to the desired amount.
2.
Go to the RF BW Management Status (2.2.4.1) screen, verify Bandwidth
Mode is “Limited” and each Sub has the correct
configured
amount.
Summary of Contents for SkyMate
Page 6: ...About This Manual vi ...
Page 20: ...Chapter 1 Getting to Know Your SkyWay Series 6 ...
Page 100: ...Appendix A RunTime Bios Application Menu Trees 86 ...
Page 102: ...Appendix B SNMP MIB Trap Messages 88 ...
Page 120: ...Appendix C Glossary and Basic Concepts 106 ...
Page 124: ...Index 110 ...