Modbus Communications
7828 Density Transmitter Technical Manual
D-4
78285000_AA
D.4
MODBUS REGISTER ASSIGNMENTS
Each register is identified by a unique number, and the list is organised by this number.
For each register, the contents are described, along with the data type of the contents.
The data type is always 32 bits unless stated otherwise. Variable names are given for
reference purposes only. They have no other use.
Note:
All units locations (registers 3, 4, 5 and 26)
MUST
be set before entering other
values.
In some cases the data in a register is used to represent a non-numerical quantity, known
as an index. For example, the units of density can be kg/m
3
, gm/cc, lb/gal or lb/ft
3
and
these are represented by the numbers 91 to 94. Thus if Register 3 (line density) contains
the value (index) 91, this means that the units of line density are kg/m
3
. Index values
may, of course, be used for more than one register.
Tables of these indices are given in section D.5.
Register
Function
Data Type
Index Table
(where applicable)
0
API product type
Long integer
D.5.1
1
API referral reference temperature
4-byte float
2
API referral reference pressure
4-byte float
3
Line density units
Long integer
D.5.2
4
Base density units
Long integer
D.5.2
5
Temperature units
Long integer
D.5.2
6
Special function calculation type
Long integer
D.5.3
7
Special function quadratic equation name
Long integer
D.5.4
8
Special function quadratic eqn. Units
1
Long integer
D.5.5
9
Output averaging time
Long integer
D.5.6
10
Analog output selected variable
Long integer
D.5.7
14
PWM factor for 4mA on analog output
Long integer
15
PWM factor for 20mA on analog output
Long integer
20
PRT calibration factor
4-byte float
21
Crystal oscillator calibration factor
4-byte float
22
Diagnostics flags
Long integer
23
Line density value when fixed by diagnostics
4-byte float
24
Base density value when fixed by diagnostics
4-byte float
25
Temperature value when fixed by diagnostics
4-byte float
26
Pressure Units
D.5.2
27
Referral temperature for matrix referral
Long integer
D.5.8
29
Alarm coverage
Long integer
D.5.9
Summary of Contents for 7828
Page 1: ...Precision measurement solutions 7828 Density Transmitter TECHNICAL MANUAL 78285000 ...
Page 4: ...7828 Density Transmitter Technical Manual iv 78285000_AB ...
Page 10: ...7828 Density Transmitter Technical Manual x 78285000_AB ...
Page 60: ...Calibration check 7828 Density Transmitter Technical Manual 5 6 78285000_AA ...
Page 66: ...Maintenance 7828 Density Transmitter Technical Manual 6 6 78285000_AA ...
Page 72: ...Specification 7828 Density Transmitter Technical Manual A 6 78285000_AB ...
Page 80: ...Calculated parameters 7828 Density Transmitter Technical Manual B 8 78285000_AA ...
Page 82: ...7828 Density Transmitter Technical Manual Safety Certification C 2 78285000_AC ...
Page 106: ...7828 Density Transmitter Technical Manual COSHH Document F 2 78285000_AA ...
Page 108: ...7828 Density Transmitter Technical Manual COSHH Document F 4 78285000_AA ...
Page 109: ......