52
© Solarbayer GmbH [02.16]
PRODUCT INFORMATION
Wood log boiler HVS
Main
tenance
Sensor
PT1000/600 sensors are used for the recording of the boiler, exhaust gas and tank temperature.
position of the boiler sensor (boiler flow line)
boiler sensor
tank sensor
exhaust
gas sensor
connection
box
When removing the front top plate you have to
unscrew the 2 self‐cutting screws at the front.
Afterwards remove the caps which are located in the
corners of the front plate with a slotted screwdriver.
Underneath the caps are self‐cutting screws which only
should be loosened. Pull the front plate approx. 2 cm to
the front and then tilt it carefully to the front.
sensor characteristics
Disconnect mains supply before removing the boiler casing.
Never touch conducting devices – danger to life exists!