PRODUCT INFORMATION
Wood log boiler HVS
Oper
a
tion
Heating up the boiler – control panel
(with exhaust gas fan)
OFF
25 kW
07:16
25.0
°
C
λ
Boiler off
This is displayed by „OFF” in the display.
The boiler starts when a pressing the „enter“ key shortly.
The control LED is green
OFF
25 kW
07:16
25.0
°
C
λ
+60
ON
Activate exhaust gas fan
select parameter
+60
exhaust gas fan is activated for 60 secs
ON
turn on boiler
0
cancel and return
▲▼
select the values that are going to be displayed
OFF
25 kW
25.0
°
C
60s
λ
+60
ON
0
Exhaust gas fan is activated
select parameter
+60
running time of the fan is elongated for 60 s/press
ON
turn on boiler
0
turn off exhaust gas fan
▲▼
select the values that are going to be displayed
ON
07:16
25.0
°
C
λ
Heating mode begins
The boiler is in heating up mode as long as the temperature is lower than the
pre‐set boiler shut down temperature
plus additional
20°C
Note: If the temperature does not cross this mark in between 30 minutes the
boiler will automatically turn to
end
90
°
C
λ
END
79
°
C
07:16
79.2
°
C
λ
Heating mode
After several minutes the boiler turns to heating mode when the shut down
temperature is exceeded by approx. 20°C
Note: The pump starts at a boiler temperature of approx. 40°C.
end
90
°
C
λ