37
June 2020
|
Solar Stik
®
, Inc.
SYSTEM SETUP AND OPERATION GUDIE FOR THE 1 kW HYBRID POWER SYSTEM (HPS)
PRELIMINARY DRAFT
d Connect PV Array(s) to PRO-Verter
Figure 19. PV array to PRO-Verter connection
Figure 20. PRO-Verter power specifications for PV arrays
PV arrays, other than the ones provided in the kit, can be connected to the PRO-Verter as long as
the power specifications for the arrays do not exceed the specifications listed on the Faceplate.
*System PV arrays: General Rules and Requirements
Connect the PV array(s)/Solar Cable to the PRO-Verter Solar Only port(s) on the front of the PRO-
Verter. For a detailed description of assembling the Array, see the Operator Manual For The Solar
Venture 300W Photovoltaic Array.
Note: Up to 880 W of PV can be connected to the PRO-Verter*.
Solar Venture 300W
one (1) or Two (2)