31
June 2020
|
Solar Stik
®
, Inc.
SYSTEM SETUP AND OPERATION GUDIE FOR THE 1 kW HYBRID POWER SYSTEM (HPS)
PRELIMINARY DRAFT
USB Charging Ports and 5 A Breaker
– For charging only. No data are transmitted via these ports.
Push to reset the breaker if either of the USB ports is not operating.
IN/OUT Breakers/Switches
– The breakers serve as switches to activate circuits and to turn off
circuits not in use. Circuit breakers protect against overcurrent conditions in dedicated circuits. If too
much amperage flows due to short-circuit, inadequate or improper loading, or component failure,
these will protect the system and operator. The green LED over each breaker will be lit if the circuit is
active and the breaker is not tripped. The 15 A PV input breakers are push/pull. The circuit for each
will be active when the breaker is pushed down.
Cooling Fan 1A Breaker
– The internal cooling fans are audible when functioning. Push to reset the
breaker if the AC Input or AC Output port is not operating while the PRO-Verter is turned on.
AGS Tech Port
– Used to program the Auto Generator Start/Stop module. Please contact Solar Stik
Technical Support for further information.
SD Card Port
– An SD card must be installed for PRO-Verter to log data. This is an optional
function. A dummy SD card is installed prior to shipment from Solar Stik.