|
49
February 2020
|
Solar Stik
®
, Inc.
System Setup and Operation Manual for ATSC MS3 L0
Advanced Information Menu
Provide detailed battery information including discharge cycles, temperature, battery-event tracking
information, and more
To Operation and Setup Menus
Days since last full charge. Day counter accuracy is
+1/-0 days, as day counter transitions occur following
the 24-hour period when battery power was applied.
Consider applying battery power late in the evening to
improve counter accuracy. Maximum range is 255 days,
which is also shown if days are unknown.
Note:
This window reports the current temperature
inside of the Power Hub, NOT the batteries. It provides
a rough estimate of the temperature of any associated
Expander Paks. The “battery temperature sensor” is
installed inside of the Power Hub. It is not possible to
reprogram this window to state that it is reporting the
temperature of the Power Hub.
Select to view activity of the three (3) charge
controllers
Captures total output amp hours on charge controller
since last cleared.
Serves as battery “odometer” capturing discharge amp
hours since last cleared. Value saved to nonvolatile
memory once per day.
Captures minimum and maximum battery voltage since
last cleared.
LAST FULL CHARGE
10 DAYS AGO
LAST EQUALIZE
22 DAYS AGO
MAX BAT VOLTS
27.4V CLR
MIN BAT VOLTS
23.9V
CLR
TOTAL CHG AMP-HR
+198AH CLR
LIFETIME BAT AH
-9886AH CLR
BAT
TEMPERATURE
25C 77F
VIEW CHARGE UNIT
STATUS SEL
ENTER SETUP
MENUS SEL