background image

Collector Top Connection:

  

 
At the collector top connection, connect the supplied 90

o

-

compression fitting. (An extension is supplied with flush 
mount kits to make installation easier)   
 
Attach the pressure relief valve unit, then the air vent 
(appearance may vary from pictures).   
 
A clean way to install is to put in a 90

o

-compression 

union at this point and drill a 1 1/2” hole directly below it 
for the roof boot flashing to be installed. Cut the shingle 
as needed and slide the roof boot flashing into place.   
 
The copper tubing will be installed into the union and the 
hole in the flashing later filled with caulk and insulated.  

 

Tighten, but do not over tighten the connections.    Be 
sure the line with the pressure relief and other valves 
on it are parallel with the roof.  The pressure relief 
valve should be tightened so it faces down directly 
onto the roof, onto the supplied aluminum splash 
sheet, for safety.  The air vent must face directly up, 
with no tilt, for proper operation.   

 

Bottom Connection of Collector:

  

 

When the end of the union is flush with the edge of the 
collector, alignment in the colle ctor is correct. 

  

 
If a straight union is installed for shipping purposes, it 
will usually be removed and replaced with a 90

o

 union.  

Use the straight unions for the tank end connections.  

 
Put in the 90o compression union at this point and drill a 
1 ½” hole directly below it for the roof boot flashing to be 
installed.  
 
Cut the shingle as needed and slide the roof boot flashing 
into place. The copper tubing will be installed into the 
union and the hole in the flashing later filled with caulk 
and insulated.  

 

NOTE:  The hole in the side of the collector will be 
covered with insulation as a final step.  All insulation 
over fittings is done last, after the system is 
pressurized, to allow for checking for leaks and 
tightening the unions as needed. 
 

Paint outside insulation with Latex paint or 
cover with aluminum tape to protect it from UV 
degradation. 

 

The 50’ roll of ½ OD copper tubing is easily unrolled and 
straitened by placing it on the ground and unrolling it as 
you lightly step in the unrolled portion.   

 

It is sometimes easiest to feed the pipe down through 
the roof boot flashing and into the tank area.  
 
A variety of techniques can be used depending on the 
situation such as needing to pull the pipe through an 
attic where it may need to come up from the bottom 
and be fed through the roof.

 

 

 

 
 
 
 
 
 
 
 
 
 

To locate the return line hole, place the 90 degree compression union on the 
upper tube and snug up.  Place the upper return assembly with air vent, pressure 
relief valve into the 90.  Center absorber in collector and make a mark 1” in 
front of the end of the tube.  Drill a 1 ½” hole centered on the mark.  

Slip the flashing under the 
PRELIFTED shingles as shown.

Summary of Contents for Fireball 20014

Page 1: ...Options 2 0 Specifications Schematics and Components 2 1 Important Notes 2 2 Collector Location Orientation and Tilt 3 0 Overview of the Basic Installation Steps 4 0 Assembling the Collector 5 0 Colle...

Page 2: ......

Page 3: ...lines Solar loop installation parts kit including miscellaneous parts fittings screws nuts bolts etc All hardware two roof boots 6 high temp insulation Installation Manual and Operation and Maintenanc...

Page 4: ...d to the floor to facilitate adequate thermosyphon action If the electric elements are not needed the Quad Rod can use the top element hole Some soldering is required to connect the Quad Rod to the Ta...

Page 5: ...g 1 2 12 7 mm OD copper 50 15 24 m Insulation 1 2 12 7 mm ID 1 2 12 7 mm or 3 4 19 05 mm wall TUBING CONNECTION METHODS standard Type Brass Union Compression Solder for Quad Rod to tank STORAGE TANK N...

Page 6: ...ded bracket tec screws 2 Color codes roof boots 3 Collector U clips per extra collector System documents and labels Top charging fill valve V1 with cap Isolation ball valve V3 Bottom charging fill val...

Page 7: ...associated with the installation of this system Do not install this system alone be sure someone knows where you are and what you are doing at all times In all cases where a firewall drywall is penetr...

Page 8: ...can help year round performance In most areas with heavy winter overcast a solar collector s orientation on a low pitched roof can face anywhere from 45 degrees east to west of south without losing m...

Page 9: ...op filled finish insulating lines Fill Tank Element or Gas turned back on 5 0 ASSEMBLING THE COLLECTOR Split Kit Only Step One Open the collector box and assemble the collector about hour NOTE To make...

Page 10: ...ood procedure suggests that you always secure your ladder to the gutter so it does not slip Place blocks in the gutter so the weight of the ladder does not crush the gutter Protect the surface of the...

Page 11: ...ctor overhang find and mark Rafters for the Three Collector Rails shown in this picture are 3 rails for 3 collectors Use a chalk line to get the 3 rails even at the bottom Get the center rail as close...

Page 12: ...a smaller bit than the lag to prevent cracking shake shingles GETTING THE COLLECTOR ONTO THE ROOF Use wisdom when pulling collectors up onto the roof have the collector at a good angle to the roof out...

Page 13: ...MAKING TUBE CONNECTIONS The tube connections top and bottom shown in top view as 3 5 are made at the top and bottom of ONE end of the collector The connections can be at either end of the collector s...

Page 14: ...on Two Three and Four Collector Flush Mount Installations Place the first collector in place with mounting bracket tabs inserted for final assembly Tighten down the lags Place three Quick Mount clips...

Page 15: ...o drilling see Section 8 top and bottom connections NOTE sound out your roof to be sure no rafters are under where holes will need to be drilled Preposition the roof boot where it will go when the pip...

Page 16: ...me around it and placing it back in place with a few finish nails INFILTRATION AND FIRE STOPS In all situations remember that infiltration is one of the main sources of energy loss in a house In no wa...

Page 17: ...mining The Pipe Run birds eye view Look for the following Second Floor First Floor Basement vent pipe feed furnace a c return solar water tank fireplace vent pipe chase a c return chase Note solar pip...

Page 18: ...NO YES Duct Chase Solar Lines Closet Solar Lines vent line chase block and seal holes and firestops chase cut hole to access firestop seal and replace...

Page 19: ...the diagrams which show the parts off the end of the collector for illustrative purposes If you have not already done so pull the aluminum tabbed tape off the top and bottom absorber connection and pu...

Page 20: ...nections Put in the 90o compression union at this point and drill a 1 hole directly below it for the roof boot flashing to be installed Cut the shingle as needed and slide the roof boot flashing into...

Page 21: ...working alone it may be easier to unroll the tube in the attic or first floor and send the tubing up and through the roof boot from the attic Fully insulate all lines Press about of supplied high tem...

Page 22: ...re the power to the element is turned off remove the lower tank element cover Install the other sensor tightly between the insulation and the inner metal tank at the lowest point possible Wire nut the...

Page 23: ...t and then attach female end of silver union with Tee and 1 2 FPT adaptor onto male end 3 Making sure that the Quad Rod is as low as possible and that the top Water Port C is level to or even better l...

Page 24: ...the pump The pump plugs into the Differential control or the optional PV pump is simply connected to the PV panel wires Locate the Differential control in a convenient place It is often mounted onto...

Page 25: ...3 and fill the solar loop with water through V1 and allow water to flow out a hose connected to V2 to flush the solar loop Close V2 allow pressure to build to 30 pounds close V1 and check the system f...

Page 26: ...least 18 inches above the bottom of the Quad Rod as shown If this is not possible then a pump can be added to the water side of the Quad Rod with the wiring connected in Parallel with the solar loop p...

Page 27: ...e lower element it is important to be aware that you will have less continuous supply of water on cloudy days because only the upper element is heating the water By staging the use of water not having...

Reviews: