58
12. DISTANCE MEASUREMENT
4. Press
[HVDOUT-T]
or
[HVDOUT-
S]
to measure the distance and
output the data to peripheral
equipment.
5. Press
[STOP]
to stop outputting
data and return to Obs Mode.
The following explains coordinate measurement and the features used to output
measurement data to a computer or peripheral equipment.
Interface cables: "36.2 Optional accessories"
Output format and command operations: "Communication manual"
PROCEDURE
1. Connect CX and host computer.
2. Allocate the
[NEZOUT-T]
or
[NEZOUT-S]
softkey to the OBS
mode screen.
• Pressing the softkey outputs
data in the following format.
[NEZOUT-T]
: GTS format
[NEZOUT-S]
: SET format
3. Sight the target point.
12.5 Coordinate Measurement and Outputting the
Data