17. OFFSET MEASUREMENT
78
2. Sight the offset point and press
[DIST]
in the first page of the
Meas mode screen to begin
measurement.
The measurement results are
displayed. Press
[STOP]
to stop
the measurement.
3. Press
[OFFSET]
in page three of
Meas mode to display <Offset>.
4. Enter the instrument station data.
C
"12.1 Entering Instrument
Station Data, PROCEDURE
Reading in Registered
Coordinate Data".
5. Select “Offset/Angle” in <Offset>.
6. Accurately sight the direction of
the target point and press
[OK]
.
The distance and angle of the
target point are displayed.
7. After finishing measurement,
press
[YES]
to return to <Offset>.
Stn. Orientation
Offset/Dist
Offset/Angle
Offset/2D
Offset
C