27. CHECKS AND ADJUSTMENTS
148
5. Calculate the additive distance
constant K as follows.
K = AB - (CA+CB)
6. Repeat steps 1 to 5 two or three
times.
If the additive distance constant K
is within ±3mm even once,
adjustment is unnecessary.
If it always exceeds this range,
have your Sokkia service
representative perform an
adjustment.
When the dividing line (the position where it switches back and forth from red to
green) for the red and green guide lights is off centered from the reticle lines, use
the following procedures to make adjustments.
G
• The guide light is an optional function. Set "Illum. Hold" to "Guide" in Config.
mode, Use the setting page to select, check and adjust the guide light.
C
"25.1 EDM Settings", and "31. OPTIONAL ACCESSORIES"
X
PROCEDURE Checks
1. Install a prism at a point about 20
meters in the horizontal direction
from the SET.
2. Level the instrument.
3. Sight the center of the prism with
the telescope (face left).
4. Hold
{
J
}
down to turn the guide
lights on.
27.8
Guide Light
X130R_27.FM 148 ページ 2003年10月15日 水曜日 午前9時38分
Summary of Contents for 130R Series
Page 8: ...vi X130R book vi ページ 2003年10月8日 水曜日 午後12時53分 ...
Page 176: ...33 REGULATIONS 168 CE Conformity Declaration X130R_33 FM 168 ページ 2004年1月13日 火曜日 午後4時49分 ...
Page 177: ...169 33 REGULATIONS X130R_33 FM 169 ページ 2004年1月8日 木曜日 午前11時5分 ...