143
27. CHECKS AND ADJUSTMENTS
X
PROCEDURE Check 1: Perpendicularity of the reticle to the horizontal axis
1. Carefully level the instrument.
2. Align a clearly visible target (the
edge of a roof for example) on
point A of the reticle line.
3. Use the telescope fine motion
screw to align the target to point B
on a vertical line.
If the target moves parallel to the
vertical line, adjustment is
unnecessary. If its movement
deviates from the vertical line,
have your Sokkia service
representative adjust it.
X
PROCEDURE Check 2: Vertical and horizontal reticle line positions
G
• Perform the check procedure under slightly hazy and weakly scintillating
conditions.
1. Install a target at a point about
100m in the horizontal direction
from the SET.
2. Level the instrument carefully, turn
on the instrument's power.
27.5
Reticle