
57
14. SETTING-OUT MEASUREMENT
Setting-out measurement is used to set out the required point.
The difference between the previously input data to the instrument (the setting-
out data) and the measured value can be displayed by measuring the horizontal
angle, distance or coordinates of the sighted point.
The horizontal angle difference and distance difference are calculated and
displayed using the following formulae.
• Setting out data can be input in various modes: slope distance, horizontal
distance, height difference, coordinates and REM measurement.
• In slope distance, horizontal distance, height difference, and coordinate mode,
registered coordinates can be recalled and used as setting-out coordinates. In
slope distance, horizontal distance and height difference, S/H/V distances are
calculated from the read in setting-out coordinate, instrument station data,
instrument height, and target height.
• Setting-out measurement can be carried out effectively using the Guide light.
C
"4.1 Parts of the Instrument", "5.1 Basic Key Operation" and
"31. OPTIONAL ACCESSORIES"
• EDM settings can be set in the Setting-out measurement menu.
• If not measured or the space is left blank “Null” will be displayed.
If distance or angle of setting-out data is set to “Null” the Distance difference is
automatically set to “Null”.
Horizontal angle difference
dHA = Horizontal angle of setting-out data - measured horizontal angle
Distance difference
Distance
Displayed item
Sdist: S-O S =measured slope distance - slope distance of setting-out data
Hdist: S-O H =measured horizontal distance - horizontal distance of setting-
out data
Vdist: S-O V =measured height difference - height difference of setting-out
data
X130R_14.FM 57 ページ 2003年10月14日 火曜日 午後8時48分
Summary of Contents for 130R Series
Page 8: ...vi X130R book vi ページ 2003年10月8日 水曜日 午後12時53分 ...
Page 176: ...33 REGULATIONS 168 CE Conformity Declaration X130R_33 FM 168 ページ 2004年1月13日 火曜日 午後4時49分 ...
Page 177: ...169 33 REGULATIONS X130R_33 FM 169 ページ 2004年1月8日 木曜日 午前11時5分 ...