13. RESECTION MEASUREMENT
50
N, E, Z of an instrument station is determined by the measurement.
• Between 2 and 10 known points can be measured by distance measurement,
and between 3 and 10 known points by angle measurement.
X
PROCEDURE
1. In the second page of Meas mode
screen, press
[MENU]
, then select
"Resection".
2. Select “NEZ” and input the known
point.
After setting the coordinates for the
first known point press
[NEXT]
to
move to the second point.
When all required known points
have been set, press
[MEAS]
.
• When
[READ]
is pressed,
registered coordinates can be
recalled and used.
C
"12.1 Entering Instrument
Station Data, PROCEDURE
Reading in Registered
Coordinate Data"
• Press
{ESCAPE}
to return to the
previous known point.
3. Sight the first known point and
press
[DIST]
to begin
measurement.
The measurement results are
displayed on the screen.
• When
[ANGLE]
has been
selected, the distance cannot be
displayed.
13.1
Coordinate Resection Measurement
REM
Resection
Area calculation
Set-out line
Point projection
m
2 n d P t .
READ
REC
NEXT
MEAS
Resection.
NEZ
Elevation
1 s t P t .
C