pg. 11
OPERATION MODES
Standard Mode
This mode is the default operating mode when first plugged in. The on & off cycling is thermostatically
controlled automatically by the HydroMate®
unit’s SMARTCHIP . As the water temperature naturally cools
2-3 degrees the temperature sensor will activate the HydroMate® pump to reheat the water to the desired
temperature.
Overnight Mode
When this mode is selected the unit will not operate for a heat call or filter cycle during the
twelve hours following mode activation. This will repeat daily. When in this mode the unit will operate normally
for 12 hours and standby for 12 hours. The unit must be up to the desired temperature on the LED display
(ex:104°F) before initializing this setting.
To enter this mode, Press and hold the
Light
button,
Jets
button & the
ꓥ
button
together for 10 seconds, 12 will display on the control panel for 5 seconds to let you
know that you have entered this mode. The heat and filter LED’s will flash twice every
15 seconds to alert you that this mode is activated. The unit will not cycle on for twelve
hours after entering this mode. The following 12 hours the unit will cycle when needed
to filter/heat the water.
Economy Mode
When this mode is activated the HydroMate
®
will turn on once per day to filter and heat the
tub to the desired temperature. This operation will repeat daily at the same time. This will take place at the time
of day that this mode was 1
st
initialized. The unit must be up to the desired temperature on the LED display
(ex:104°F) before initializing this setting.
To enter this mode, Press and hold the
LIGHT
button
and the
ꓥ
button together for
10 seconds, 24 will display on the control panel for 5 seconds to let you know that
you have entered this mode. The filter LED light will flash once every 10 seconds to
alert you that this mode is activated. When this mode is selected the unit will cycle
once per day to filter/heat water. This cycle will occur at the same time each day this
mode was activated.
NOTE:
All modes can be reset/stopped if the HydroMate
®
is unplugged for 15 seconds. After a power
reset, optional mode will need be re-programmed.
Display Codes
•
IPS
– Insufficient Power Supply -
The supplied power is insufficient and the HydroMate
®
has turned
off to protect the internal electronic components.
•
P
– Purge -
A “P” will be displayed when the pump is not on, to indicate that the water near the
temperature sensors must be purged to get an accurate reading of the water temperature.
•
P01 -
This code indicates temperature sensor has not seen a change in temperature while the pump is
running of 1 degree over a period of 4 hours.
Note:
Unplugging the HydroMate
®
for 10 seconds will reset\remove the error code and unit should run
as desired. Any special settings will need to be re-programmed.