10.5 Examples
This section provides an example of a typical design.
Figure 87 : Example of a typical office plan
Zone 1: This zone is a conference room with hard floor and suspended ceiling tiles. The room is
approximately 920 sq. ft. Four loudspeakers are required, each one covers 230 sq. ft.
Zone 2: This zone is a hallway covered with sound masking to provide homogeneity of the
masking sound in the entire building.
Zone 3: The bathrooms have a gypsum ceiling and a ceramic floor. The acoustic room response
is very different from the other zones of the building.
Zone 4: This zone is a waiting room near the reception. This area is approximately 320 sq. ft.
Zone 5: This zone is above the reception desk. It is separated from zone 4 in order to reduce the
sound masking level above the reception independently from zone 4.
Zone 6: This zone covers all the closed offices in that section of the building. In this case, one
loudspeaker is installed above each office. The total area is 1320 sq. ft., each
loudspeaker covers approximately 220 sq. ft.