6.6 Offline Mode
The Offline Mode allows some of the software measurement capabilities to be used without being
connected to the SmartSMS unit. The Offline Mode can be used to equalize the system manually,
without any wireless system or long microphone cable. To run the software in the Offline Mode and
to be able to perform measurements, a Soft dB Precision microphone connected to the PC with an
IMIC device is required.
Note: The SMS unit must be running if you want to carry out a masking sound measurement. To
begin the offline mode calibration, start the masking noise, and save the configuration on the PC.
Disconnect from the SMS unit.
To start in the Offline Mode, simply launch the SmartSMS software without being connected to the
SmartSMS unit. A selection window will then appear. Click on YES to start in the Offline Mode.
Figure 59: Dialog box for the selection of the Offline Mode
Then, you must select the appropriate configuration file to be able to use the Test Calibration
function and other functions in the Offline Mode. If you do not specify a configuration file, only the
spectrum analyzer will be available.
Figure 60: Asking for the CFG file in the Offline mode
In the Offline Mode, the Main window of the software is displayed, but some of the functions are not
available.