![Soft dB SmartSMS 2 User Manual Download Page 62](http://html1.mh-extra.com/html/soft-db/smartsms-2/smartsms-2_user-manual_1312055062.webp)
SmartSMS User Manual
Soft dB inc.
User Manual
p. 62
Figure 53: Masking Spectrum assignment interface
Use the Change/Define Mask button to modify a specific mask or to add a new mask to the list.
6.5.6 Copy/Paste
The Copy/Paste function can be used to copy the setting for a selected zone (channel) to another
zone or other zones. Simply select the source channel (corresponding to a given zone) and select
the destination channel(s).
6.5.7 Set-up Diagnosis
The Set-up Diagnosis function offers access to the measurements performed for each channel.
This information is useful to verify whether the identification noise is louder than the background
noise (which is necessary to ensure the effectiveness of the automatic equalization process) or not.
Also, this information allows you to verify whether the background noise has exceeded the value of
the target masking spectrum. The maximum output for each channel can be visualized to detect a
saturation problem.