BT-T080R User’s Manual
- 45 -
Errors which can recover automatically:
Error
Description
ERROR LED
Buzzer
Recovery
Print head
overheating
Temperature of
the print head is
over 65
℃
.
Recover automatically
when the temperature
of the print head is
less than 60
℃
.
Print head
uplifting
Print head is
uplifted, and the
printing stops.
Recover automatically
when the print head is
closed, and the
printing recovers
automatically without
losing print content.
Voltage is
too high
The voltage of
the power is over
26.4V
Automatic recovery
after the voltage is
less than 26.4V.
Voltage is
too low
The voltage of
the power is less
than 21.6V.
Automatic recovery
after the voltage is
over 21.6V.
Table 7.1.3 Auto-recovery error
Errors which can recover possibly:
Error
Description
Error LED
Buzzer
Recovery
Auto cut
error
The auto paper
cutting is
abnormal.
Exclude the error
through DLE ENQ 1 or
DLE ENQ 2 command
after the paper jams in
cutter is cleared.
Mark
detection
error
Can not detect
the mark.
No buzzing.
Exclude the error
through DLE ENQ 1 or
DLE ENQ 2 command
after the marked paper is
loaded.
Table 7.1.4 Possible recovery error