68
5.7-7
5.7-8
5.7-9
* = Preset by the manufacturer
Operation “
MODE
”
Code C4
Figure 5.7-7
Eventual residual clamping device imbal-
ance compensation.
High precision measuring (This operating mode cannot
be stored in the permanent memory).
Once compensation has been performed, if the clamp-
ing device is changed, this value must be deleted or
recalculated using the new device.
To delete clamping device compensation , set the
operating state to 0.
Compensation should be deleted when the machine
is calibrated or recalibrated, if imbalance optimisation
(silencing) is performed or if the machine is turned OFF
.
0
= Perform compensation
1
= Compensation performed
0
= Disable compensation after the measuring run.
Code C5
Figure 5.7-8
Braking of the wheel when the wheel
guard is opened during the measuring run
0 =
No braking
The wheel rotates when the wheel guard is open.
Make sure that the wheel is not blocked by a tool or
similar item.
Wear safety goggles and tightly fi tting working clothes.
1* =
Braking
The selected mode of operation can be transferred to
the permanent memory.
Code C6
Figure 5.7-9
Entering the number of wheel spins per
measuring run. Between 5 and 25 spins are possible,
preset by the manufacturer at 10 spins per run.
Example > change to 15 spins per run.
WARNING: REDUCING THE NUMBER OF SPINS
PER RUN MEANS THAT THE MEASUREMENT WILL
BE LESS PRECISE.
The operating mode selected can be obtained from
the permanent memory.
Summary of Contents for Sun SWB 100