24
torque is recalibrated, calibration counter is automatically reset to zero. User can disable
calibration interval check and use number of cycles since last calibration to decide when to
recalibrate.
Note: If an invalid date is entered and Calibration interval is enabled, an unintended "CAL NEEDED"
message may be displayed. Either disable calibration interval or enter a correct date.
Change Password
Change Password function allows user to change password to a new password. Default password is
required to initially change password.
Refer to ControlTech™ Micro Calibration Manual for default
password.
1.
From Configure menu, use
UP/DOWN
buttons to highlight CHANGE PASSWD selection then press
ENTER
button.
2.
Initial password entry screen is displayed.
3.
Enter default password if changing for first time, otherwise enter current user password using
UP/DOWN
buttons to change each digit followed by
ENTER
button.
4.
Change password entry screen is displayed.
5.
Enter new password using
UP/DOWN
buttons to change each digit followed by
ENTER
button.
6.
Confirm password entry screen is displayed.
7.
Re-enter new password using
UP/DOWN
buttons to change each digit followed by
ENTER
button.
Note: Pressing
POWER
button at any time aborts password change sequence.
Note: If an invalid password is entered during confirmation step, Invalid Password Match screen is
displayed and new password is not accepted.
INVALID
PASSWD MATCH
PRESS TO CONT.
SET DATE/TIME
SET CAL INTRVAL
CHANGE PASSWD
ENTER PASSWD
0
0 0 0 0
ENTER
button
UP/DOWN
buttons
ENTER
button
CHANGE PASSWD
0
0 0 0 0
UP/DOWN
buttons
ENTER
button
CONFIRM PASSWD
0
0 0 0 0
UP/DOWN
buttons
Previous password entry screen
New password entry screen
Confirm password screen