10
range by pressing
UP/DOWN
buttons. Once desired minimum torque value has been set, press
ENTER
button
.
6.
MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above which red
progress lights turn on. Initial MAXIMUM TORQUE value will be TARGET TORQUE value plus positive
torque tolerance (default 4%, see MODE SETUP in Advanced Configuration section). Maximum
torque value can be set greater than TARGET TORQUE value to 10% above wrench maximum range
by pressing
UP/DOWN
buttons. Once desired maximum torque value has been set, press
ENTER
button
.
7.
BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP/DOWN
buttons to increment/decrement batch count. Mode Count increments each time
target torque is reached if a batch count of zero is entered. Mode Count decrements if a non-zero
batch count is entered and resets to batch count value when count reaches zero. Once desired
batch count value has been set, press
ENTER
button
.
8.
PSET target screen is displayed labeled with next available PSET number from 01 to 50.
9.
To enter additional torque presets, repeatedly press
ENTER
button
until target torque screen is
displayed and repeat steps above.
Adding an Angle Preset
1.
From manual target angle screen, press and hold
UNITS
button
for 3 seconds.
2.
ADD PRESET confirmation screen is displayed. Highlight
YES
menu selection using
UP/DOWN
buttons then press
ENTER
button
.
NO
menu selection returns to main menu without adding a PSET.
3.
TARGET ANGLE screen is displayed. TARGET ANGLE is fastener rotational angle target value. Initial
TARGET ANGLE value is value from target angle screen. TARGET ANGLE can be set from 0 to 360°
by pressing
UP/DOWN
buttons. Once desired target angle value has been set, press
ENTER
button
.
4.
MINIMUM ANGLE screen is displayed. MINIMUM ANGLE is value at which green progress lights,
audible alert and vibrator turn on. Initial MINIMUM ANGLE value is TARGET ANGLE minus negative
angle tolerance (default 0%, see MODE SETUP in Advanced Configuration section). MINIMUM
ANGLE can be set from 0 to TARGET ANGLE by pressing
UP/DOWN
buttons. Once desired minimum
angle value has been set, press
ENTER
button
.
5.
MAXMUM ANGLE screen is displayed next. MAXIMUM ANGLE is angle value above which red
progress lights turn on. Initial MAXIMUM ANGLE value will be TARGET ANGLE plus positive angle
tolerance (default 4%, see MODE SETUP in Advanced Configuration section). MAXIMUM ANGLE
value can be set to any value greater than TARGET ANGLE by pressing
UP/DOWN
buttons. Once
desired value has been set, press
ENTER
button
.
6.
BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99. Press
UP/DOWN
buttons to increment/decrement batch count. Mode Count increments each time
target angle is reached if a batch count of zero is entered. Mode Count decrements if a non-zero
batch count is entered and resets to batch count value when count reaches zero. Once desired
batch count value has been set, press
ENTER
button
.
7.
PSET target screen is displayed labeled with next available PSET number from 01 to 50.
ENTER
button
ENTER
button
UP/DOWN
buttons
ENTER
button
UNIT
button
held
Target Torque Screen
UP/DOWN
buttons
UP/DOWN
buttons
ENTER
button
ENTER
button
UP/DOWN
buttons
ENTER
button
UP/DOWN
buttons
Preset Torque Screen
00
100.0
IN-LB
ADD PRESET
YES
NO
ADD PRESET
YES
NO
TARGET TORQUE
100.0
IN-LB
MINIMUM TORQUE
100.0
IN-LB
MAXIMUM TORQUE
104.0
IN-LB
BATCH COUNT
3
PSET 01
03
100.0
IN-LB
Summary of Contents for ControlTech Micro