Maintenance
58
NOTE: I T W I L L B E N E C E S S A RY TO I N S TA L L T H E
CALIBRATION BAR ADAPTER (EAK0289J42A)ON
THE END OF THE CALIBRATION BAR WITH THE FLAT
SPOTS. THIS WILL ENSURE A SMOOTH ROTATION
OF THE BAR DURING CALIBRATION
Place the calibration bar and stands on the rear of the rack. Place
7.
the bar so that the numbers stamped on the bar are on the left
side runway. Install the EAK0289J42A Bar Adapter on the end
with the numbers with the set screws at 12 o’clock.
Place the left pod on the calibration bar
8.
so that the boom faces the rear of the
rack.
Place the right pod on the calibration
9.
bar so that the boom faces the rear of
the rack.
Place the targets on the front turn plates
10.
and orient the so that they are facing the
pods. It will be necessary to leave the
targets mounted to the wheel clamps.
Select the appropriate rack for calibration
11.
Rack A, Rack B or Floor
With the Pods locked on the bar rotate the bar forward 90° to align the
12.
needle within the green area. A Stop sign will appear indicating
to hold the position until instructed.
Continue through the process stopping at
13.
each location until the front pods have
been calibrated. Proceed to the next step
to complete the Front Target calibration.
Summary of Contents for EEWA717A
Page 1: ...Form ZEEWA717A Operators Manual EEWA717A and EEWA719A Aligner Systems ...
Page 2: ...Blank page ...
Page 6: ......
Page 65: ...Notes ...