RED-G
23
REV.9 PRINTED 02/2018
LIFT SYSTEM
RED-G3000
RED-G4000
3-Phase Mains
3~380-415Vac 50Hz / 60Hz, with neutral
(optional)
3-Phase Gearless Lift Motor Power
Up to 16kW
Up to 21kW
Max current through power supply connection
(See pag. 28)
Up to 40A
Up to 53A
RESCUE OPERATION
Recommended motor speed during rescue operation
1/20 normal speed
3-Phase Output Voltage
3~400Vac, with neutral (optional)
3-Phase Output Frequency
50Hz / 60Hz
(See page 36)
3-Phase Rated Output Power
3kVA
4kVA
3-Phase Output Overload
120% Rated Output Power for 10sec.
Output Voltage Waveform
Sinusoidal
Modified sine wave
output
Rescue Operation Time Out
3 min / 15 min
(2kVA max)
3 min /15 min
(3kVA max)
Circuit-Breaker Protection (IE)
63A
BATTERIES AND BATTERY CHARGER
Battery Type
Sealed and Maintenance free Lead Acid
Nominal battery Voltage
48V (N°4 units 12V in series)
Battery Capacity
18Ah minimum (Batteries Outside)
(See page 4)
Battery Maximum Voltage
54V
Battery Charger Output Current
2,5A
Battery Charger Input
230Vac 50Hz / 60Hz +8/-15% 0,8A
MECHANICAL DATA
Dimensions (WxHxD) mm
384 x 527,5 x 180 (without side handles)
Enclosure Protection
IP20
Weight (without batteries)
45kg
ENVIRONMENT
Ambient Temperature
0°C 45°C
Humidity
Up to 95% non-condensing
Altitude
1000m without derating (max 2000m)
Storage Temperature
-25°C 70°C
TECHNICAL DATA RED-G 3000 / RED-G 4000
D
ATI
T
ECNICI
RED-G 8000
Summary of Contents for RED-G 3000