20 | SmithsEP.co.uk | Issue 001 - November 2018
Basic setting enabled
Temperature control for Comfort
(COMF) enabled
SS3E
How to operate
1. Ensure your fused spur is switched ON
2. Ensure the wireless controller is switched ON
3. Ensure the heater is paired with the wireless
controller
4. Ensure the wireless controller is switched on
and calling for heat
5. Switches on the right hand side of fascia
control heat output:
A. For 1kW heat output press left hand switch
only (switch illuminates)
B. For 2kW heat output press right hand
switch only (switch illuminates)
C. For 3kW heat output press both switches
(switches illuminates)
6. To turn the heater OFF set the controller
switch to OFF (heating symbol not shown
on display)
Space Saver is fitted with an electronic safety (ES)
control which is a safety device which switches
off the heater, if for any reason, the appliance
overheats. The ES controls can only be reset after
the appliance has cooled down in order to reset
the ES control see fault finding.
600
586
380
86
97
165
60
110
9
110
1kW
2kW
3kW
1. Ensure your fused spur is switched ON
2. Ensure the wireless controller is switched ON
4. Ensure the wireless controller is paired (page 9)
with the heater
5. Set the thermostat to the desired temperature
up to the maximum set during the
installation process
A. For 1kW heat output press left hand switch
only (switch illuminates)
B. For 2kW heat output press right hand
switch only (switch illuminates)
C. For 3kW heat output press both switches
(switches illuminates)
6. To turn the heater OFF, set the controller
switch to off (heating symbol not shown
on display)
For your safety this Kitchen Heater is fitted with
an automatic overheat protection. If the heater
stops, turn off the power at the fused spur, wait 5
minutes and switch the power back on.
600
586
380
86
97
165
60
110
9
110
1kW
2kW
3kW