12 | SmithsEP.co.uk | Issue 001 - November 2018
2.
Temperature control for
Comfort (COMF)
Switch 1 controls the display screen. If it is set to
’ON’ the temperature is displayed as Fahrenheit.
If it is set to ‘OFF’ the temperature is displayed
as Celsius.
Installation - with
advanced features
ON
1
2
3
4
1.
Getting to know your
battery controller
The controller has a number of advanced
features that, if required MUST be set during
the installation process. Please discuss with your
customer which features they require. The dip
switches will need to be set prior to attaching the
thermostat to the back box.
•
Temperature control for Comfort (COMF)
This can be set to limit the maximum
temperature set by the user.
•
Temperature control for Setback (SETB)
This can be used for frost protection or situations
where a minimum room temperature must be
maintained. The setback temperature can be set
between 0°C and 15°C.
•
Run-back Timer
This can be used to limit the run time of the
heater from between 5 minutes and 2 hours.
The Run-back Timer cannot used be used in
conjunction with Temperature control for
Setback (SETB).
temperature
adjustment
buttons
temperature
display screen
ON/OFF
button
Heating status symbol
Solid
- heating active
flashing
- heating inactive,
room at set temperature
not shown
- heating inactive
Temperature can be
displayed in °C or °F.
This can be changed
by SW1.
Temperature not flashing
-
indicating room temperature
Temperature flashing
-
indicating set temperature when
using UP or DOWN buttons
ON
1
2
3
4
Variable resistors to set
maximum comfort and
setback temperatures
Prior to installation the maximum comfort
temperature can be adjusted using the knob
marked COMF located at the back of the
controller as shown below. The range is 15°C to
35°C. The maximum comfort temperature limits
the temperature that can be set by users after
installation. After installation, the user can adjust
the temperature using the UP and DOWN buttons,
in the range from 15°C up to the maximum
temperature set by the knob marked COMF.
After pressing the ‘ON’ button the heating
will operate until the set room temperature is
achieved, at this point the heating status symbol
on the display will start flashing. When the room
temperature drops the heating will become active
again and the heating status symbol will change
from flashing to steadily on.
The display screen will show the actual room
temperature, except briefly when either of the two
adjustment buttons are pressed, the new target
room temperature is then temporarily displayed.
Note: After changing any settings, in order for the
change to take place, the controller has to be set
to heating inactive status.
Radio transmit symbol
will flash every time a
signal is sent