1.
Cut the opening in the plinth
• To ensure adequate airflow, a minimum
clearance of 20mm (10mm for SS80E product)
between the top of the product and any
shelving is essential
• To avoid the possibility of vibration, this product
must be installed on a flat, even surface
• There must be no rear access to the product
after completion of the installation
• We recommend the use of a knee pad when
installing this product
• Cut the opening in the plinth to the size shown
in the table. Use method 1 or 2.
3 represents installation into a 80mm plinth
(SS80E only)
* The overall height of the grille is 100mm.
Use care when cutting the opening.
Installation - Heater
Model
Width A
(mm)
Height B*
(mm)
SS2E
475
96
SS3E
500
95
SS80
400
74
SS5 DUAL
465
96
1.
2.
A
A
B
B
3.
A
2a.
Connection for SS5 Dual
Heater - Fit isolating valves
(not supplied)
• Fit isolating valves (not supplied) to the system
flow and return pipes. In order to achieve the
highest level of performance we recommend
full bore valves.
• Failure to fit isolating valves may mean that the
product is not serviceable in the event of failure.
• Connect the flexible hoses between system
pipework and heater. Please ensure the flexible
hoses are not kinked.
• Open the isolating valves and check for leaks.
N.B. either pipe may be used on flow or return.
The Flexible installation hoses supplied are suitable
for use with either 15mm diameter copper pipe or
15mm cross-linked polythene barrier pipe to
BS 7291. The only type of fitting approved to
connect onto the heater are compression fittings.
2b.
Vent air through bleed
Open
Closed