Service setting (for After-Sales Service only)
See information on Smegtech
6.15
Starting the peristaltic pumps – rapid filling of detergent and rinse aid
delivery circuit.
Perform after the parameter modification procedure explained in the previous point.
Indicator lights showing: off; green; orange;
flashing.
With the glasswasher powered up, access “programming
mode” by pressing the on/off button for a few seconds; at
the “beep”, release the button and press it again
quickly
within 0.5 seconds
.
The peristaltic pumps continue to operate until the same
button is pressed again. The rinse aid and detergent symbol
lights remain on as long as the pumps are on; bear in mind
that the rinse aid peristaltic pump fills the circuit in about 7
minutes, while for the detergent it only takes 2 minutes. So
draw only rinse aid from the jerry cans (1 for the rinse aid
and the other for the detergent) for the first 5 minutes and
then also take in detergent for the last 2.
7 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR
THE TECHNICIAN)
The glasswasher is able to identify a number of malfunctions and show them on the display. If the
problem persists after the glasswasher has been switched off and back on, proceed as described below:
Err01
The anti-flooding system has
been activated (for the
relevant models only).
Large water leak: check the origin of the problem.
Err04
Tank temperature probe
malfunction
Tank temperature probe disconnected or not working.
Err05
Tank water filling malfunction
The tank does not fill within the allowed time: check water intake
tap, dynamic pressure in intake system, cleaning of water intake