20
8,3
24
10,0
30
11,7
36
13,3
42
15,0
6.7
Autostart function
Modify the parameter (ON/OFF) by pressing
.
Set at “on” to start the cycle when the door is closed.
Set at “off” for cycle start after confirmation with the start button
6.8
Regeneration frequency setup (models with softener)
•
(Default value:
H03
; modify the parameter to suit the mains water hardness.
•
At first use, the salt tank has to be filled. It is subsequently sufficient simply to fill up with
regenerating salt when necessary.
Modify the
value of the
parameter by
pressing .
Hardness
(°dH German
degrees)
Hardness
(°dF French
degrees)
Setting
level
Regeneration
off
Regeneration
off
H00
8,5
15
H01
11
20
H02
17
30
H03
22,5
40
H04
28
50
H05
Regeneration cycle duration:
12 minutes
33,5
60
H06
With values over 60°dF an external water treatment device must be used and the regeneration
frequency
must be set on H00
.
6.9
tStP (minimum rinsing temperature) function
Modify the parameter (ON/OFF) by pressing
.
Summary of Contents for PROFESSIONAL GLASSWASHER