User Manual
GW2145 - GW1160 - GW4060 - GW4190
Page 44 - 86
fig. 32 – "
Set - t
" value can be "--" or "
on
". In this latter case a test cycle will be activated.
5.3.1
APPLIANCE DATA STORAGE, OVERWRITING, “Set -b”
The appliance stores the data relating to the
cycles performed
and all the
alarms which have occurred
in its own
internal memory
, on a PCB.
The data in the appliance’s memory can be read using the
Smeg TRACELOG
software.
Overwriting of the data in the appliance’s memory can be enabled or disabled using a setup parameter,
Set
:
-b
– ; for
section.
Parameter
Set
-b
has two possible values:
- “
0
” meaning “
overwriting disabled
”
- “
1
” meaning “
overwriting enabled
” –
1
is the
default value
for the parameter; overwriting is permitted and no alarm
is triggered when the appliance’s memory is full.
WARNING
If overwriting is disabled,
parameter “-b=0”
,
alarm
AF:91
is triggered once the memory is full.
In this case the appliance is cut out and will not perform any more cycles
until the data from the
memory are downloaded to free spaces; this can only be done using the TRACELOG software.
fig. 33 –
SET
appliance parameters; parameter –
b
is used to enable and disable overwriting of the internal data memory.
The following is an example of data stored in the internal memory, with a key to their interpretation.
The data can be accessed using the TRACELOG software.