5.1
ACCESSING THE SETUP MODE / ENTERING THE PASSWORD
a.
Hold the
Functions
button (5) down for 5 seconds. 4 dashes appear on the display.
b.
Use the
Selection
buttons (4-8) to modify the individual characters of the password.
c.
Short press the
Functions
button (5) to move on to the next character
d.
Once the 4 characters of the password have been entered, confirm by holding down the
Start/Stop
button (3).
a.
If the password entered is correct, the system accesses the first menu item
b.
If the password is not correct, two
beeps
signal the error.
c.
5 seconds after the last button is pressed, the system automatically quits the Setup menu.
e.
Once the Setup mode has been accessed, the various
items
available can be scrolled using the
Functions
button
(5).
f.
Note on GW4060, GW4190 series: a short press on the button
(6) has the same meaning of the short
press on button
Functions
(5) in the following cases:
a.
When entering password, to switch from one character to the next.
b.
Going into the setup mode, to scroll through the various items available.
fig. 27 –
Functions
button: hold down to access the Setup mode.
The
items
accessible from the
SETUP
menu are shown in the table below. To move on from one
item
to the next,
press the “
Drying
” button.
Setup Item
Description
Set
Appliance parameter setup - detailed explanation provided below in “Set” Parameters
Cloc
Date and time - detailed explanation provided below in “Cloc” Parameters
Filt
Drying filter counter.
(Only for GW4060, GW4190 series)
Press the
Start/Stop
button to display the
number of absolute filter hours left before the
maintenance message appears.
The initial default setting is 500. The value is in units.
(Display only parameter, cannot be modified).
Tec
Appliance operating hour adds up towards maintenance. Press the
Start/Stop
button to
display the
number of cycles left before the maintenance message appears.
The initial
default setting is 900. The value is in units. (Display only parameter, cannot be modified).
Coun
Appliance total operation counter (display only parameter, cannot be modified)
PrEn
Setting which allows display and selection only of the washing programs actually of
interest.