fig. 57 – Drain connection. 65 cm < H < 80cm, X < 20cm. Suffix "C" on the name of the model indicates "equipped with steam condenser", in this case
n.ro 2 drain pipes are provided.
WARNING
The drain must comply with international regulations
: our company accepts no liability for
pollution caused by improper use of the appliance.
fig. 58 – Adapter with connector for 1/2" hose.
General guidelines for installing the drain
The use of a drain with syphon trap is recommended. During installation, the following precautions should be
complied with:
Since the drain water temperature is 95°C,
the end of the drain hose must be permanently connected to the hose
connector
, using the
ties
provided.
There must be no sharp bends in the drain hose which might cause restrictions.
The difference in height between the end of the drain hose and the surface on which the appliance is installed
must comply with the stated specifications.
The end of the hose must never be submerged in water.
The
inside diameter
of the drain pipe to which the hose is connected must be
at least 40 mm
.
A drain pipe
50 mm in diameter
is recommended.
No extensions must be added to the drain hose supplied with the appliance. Any extensions might cause problems
of flow-back into the chamber.