Instructions for the Installer
4.
FINAL OPERATIONS
After changing the nozzles, put the pan stands, the burner caps and
flame-spreader crowns back into place.
After adjusting for use of a gas other than the gas used for testing the
appliance, replace the gas setting label inside the storage compartment
with the label for the new gas. The label is available from your nearest
Authorised Service Centre.
4.1
Adjusting the minimum setting for natural gas
Light the burner and turn it to the minimum setting
. Extract the gas tap knob and turn the
adjustment screw inside or next to the tap rod
(depending on the model) until the correct
minimum flame is achieved. Put the knob back in
place and check the stability of the burner flame (the
flame must not go out when the knob is turned
quickly from the maximum to the minimum setting).
Repeat the operation on all the gas taps.
4.2
Adjusting the minimum for LPG gas
The diameters of the bypasses for each individual burner are stated in
point "3.2 Burner and nozzle characteristics table". When the adjustment
is complete, re-seal the bypasses with paint or another similar material.
4.3
Positioning and levelling the appliance
After making the electrical and gas connections, level the appliance by
means of its four adjustable feet.
49
Summary of Contents for CSP20-6
Page 23: ...Instructions for the user 63...