Instructions for the Installer
Operation at 380-415V 3N
∼
:
use a
H05RR-F type five-core cable (cable of 5 x
1.5 mm
2
).
Operation at 380-415V 2N
∼
:
use a
H05RR-F type four-core cable (cable of 4 x
1.5 mm
2
).
Operation at 220-240V
∼
:
use a H05RR-F
type three-core cable (cable of 3 x 2.5
mm
2
).
The end to be connected to the appliance
must have an earth wire (yellow-green) at
least 20 mm longer than the others.
The manufacturer cannot be held liable
for damage to persons or
things caused by failure to comply with the above requirements or by
tampering with any part of the appliance.
2.2
Room ventilation
The room containing the appliance should have an air supply in
accordance with B.S. 5440 part 2 1989.
1.
All rooms require an opening window or equivalent, and some
rooms will require a permanent vent as well.
2.
For room volumes up to 5 m
3
an air vent of 100 cm
2
is required.
3.
If the room has a door that opens directly to the outside, and the
room exceeds 1 m
3
no air vent is required.
4.
For room volumes between 5 m
3
and 10 m
3
an air vent of 50 cm
2
is
required.
5.
If there are other fuel burning appliances in the same room B.S.
5440 part 2 1989 should be consulted to determine the air vent
requirements.
6.
This appliance must not be installed in a bed sitting room of less
than 20 m
3
or in a bathroom or shower room.
Windows and permanent vents should therefore not be blocked or
removed without first consulting a Corgi gas installer.
Failure to install appliances correctly is dangerous and could lead
to prosecution.