Instructions for the Installer
44
2.
INSTALLING THE APPLIANCE
The appliance must be installed by a
qualified technician
and
according to the regulations in force. Corgi gas installers are approved to
work to safe and satisfactory standards. All gas installation, servicing
and repair work must be in accordance with the gas safety regulations
1984 (installation and use) as amended 1990.
This appliance may be installed next to walls, one of which must be
higher than the appliance, at a minimum distance of 50 mm from the side
of the appliance, as shown in drawings A and B relative to the installation
classes. Any wall cupboards or ventilation hoods must be at a distance
of at least 750 mm above the work surface.
A
B
Built-in Appliance
Free-Standing Installation
2.1
Electrical connection
Make sure the voltage and the cross-section of the power supply line
match the specifications indicated on the identification plate positioned in
the storage compartment.
Do not remove this plate for any reason.
The plug and wall-mounted socket must be of the same type (in
accordance with CEI regulations). Make sure that the supply line is
suitably earthed. Avoid use of adapters and shunts.
Fit the power supply line with a multipolar cut-out device with a contact
opening gap equal to or greater than
3 mm
in an easily accessible
position close to the appliance.
Summary of Contents for CSP20-6
Page 23: ...Instructions for the user 63...