Instructions for the installer
44
3.2
Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
Liquid gas – G30/G31
30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1.05
50
30
400
76
75
Semi-rapid
1.8
65
33
500
131
129
Rapid
3.0
85
45
800
218
215
Ultra-rapid
4.0
100
65
1600
290
286
Fish burner
1.9
68
45
800
138
136
Burner
Rated
heating
capacity
(kW)
CITY GAS – G110
8 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary
1.05
145
400
Semi-rapid
1.8
185
500
Rapid
3.0
260
800
Ultra-rapid
4.0
350
1200
Fish burner
1.9
190
800
The values for city gas refer to appliances in category III 1a2H3+.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20
20 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary
1.05
72
400
Semi-rapid
1.8
97
500
Rapid
3.0
115
800
Ultra-rapid
4.0
135
1600
Fish burner
1.9
94
800
3.3
Arrangement of the burners on the hob
BURNERS
1 Auxiliary
2. Semi-rapid
3
Rapid
4
Ultra-rapid
5
Fish burner