Instructions for the user
68
10.6.1
Setting the cleaning cycle with the electronic analogue clock
FUNCTION SELECTOR KNOB
ELECTRONIC ANALOGUE CLOCK
The programmer automatically sets the minimum duration of the cleaning
cycle (1 hour and 30 minutes). Within 5 seconds press key
or
to
increase or decrease the cycle time (the maximum time is 3 hours and 30
minutes). The set minutes will be shown by the internal segments of the
clockface lighting up, while the hours will be shown by the relevant
numbers flashing (1, 2 or 3). Figure 2 shows a pyrolysis cycle of 2 hours
and 30 minutes.
1)
2)
Once the automatic cleaning cycle time has been set, the oven will start
to heat up (approx. 5 seconds after the last action by the user), the oven
thermostat light will start flashing and will become steady once the oven
has reached an internal temperature of approx. 470°C;
The door lock will be activated within approx. 1 minute after the last
action by the user, shown by the relevant light coming on and symbol
on the display.
At the end of the automatic cleaning cycle, all the numbers will flash and a
buzzer will sound to indicate the end of the cycle. The door lock light will
remain lit and it will not be possible to open the door until the temperature
inside the oven falls below 300°C. Once pyrolysis is complete, set the function
selector to off.
To activate the pyrolysis cycle with delayed start, set the timer as for a normal
programmed cooking process; see “
5.2.3 Programmazione”.