Instructions for the installer
3.
ADAPTATION TO DIFFERENT TYPES OF GAS
Before carrying out the following operations, disconnect the appliance
from the electricity supply.
The appliance is preset for
natural gas G20
(2H) at a pressure of 20
mbar. In the case of operation with other types of gas, the burner nozzles
must be changed and the minimum flame adjusted on the gas taps. To
change the nozzles, proceed as described in the following paragraphs.
3.1
Replacement of the cooking hob nozzles
1.
Extract the pan racks and remove all the caps and flame-spreader
crowns;
2.
Unscrew the burner nozzles with a 7 mm socket wrench;
3.
Proceed with the replacement of the burner nozzles according to the gas
to be used (see paragraph “3.2 Burner and nozzle characteristics table”).
Replace the burners in the correct position.
The nozzles for using city gas (G110 – 8 mbar) are available from
authorised service centres.
43