Doc. No. ZQ-OM01301-A
- 17 -
4
. Solenoid valve
4.1 Manual override
There are 2 types of manual override operation. Push the manual override with a
screwdriver until it reaches the end. Confirm that the product operates safely before the
operation of the manual override.
4.2 Wiring
To install the connector, hold the cover and insert the connector straight pushing the connector
lever with your finger. Ensure that the connector lever clip is properly inserted into the groove
ofthe cover. To remove the connector, hold the solenoid valve and pull out the connector
straight pushing the
connector lever clip.
4.3
Internal circuit
With light/surge voltage suppressor A non-polar valve is installed in the product.
4.4 Initial state
When the valve assembly is delivered, the supply valve is on the OFF position, but it may be
on the ON position due to the vibration or impact during transportation or device installation.
Move supply valve to OFF position manually or energizing before use.
4.5 Precautions
1) The specified voltage must be used. Otherwise failure, malfunction or short life can result.
2) If a valve is energized for an extended period of time without a break, the rise in
temperature due to heating of the coil may cause a decline in solenoid valve performance,
reduce service life, or have adverse effects on peripheral equipment. The energized time in
one day should be shorter than the non-energized time.
3) A V100 series solenoid valve is installed in the product. Refer to the Operation Manual of
the V100 Series for details.
Manual override operation type
Nil: Non-locking push type
B: Slotted locking type
Cover
Groove
Pin
Lever
DC polarity display
connector
Varistor
Coil