background image

 

One-touch Fittings 

 
 
The pitch of the SX series piping ports (PE, A, B etc.) has been 
set assuming the use of KJ series one-touch fittings. Therefore, 
when using fittings, there may be some interference between 
fittings, depending on the type and size, so please use after 
checking dimensions in the catalog for the pipe fitting being used. 

1. Tube attachment/detachment for one-touch fittings 

1) Attaching of tubing 

  (1) Take a tube having no flaws on its periphery and cut it off 

at a right angle. When cutting the tube, use tube cutters 
TK-1, 2 or 3. Do not use pinchers, nippers or scissors, etc. 
If cutting is done with tools other than tube cutters, there 
is the danger that the tube may be cut diagonally or 
become flattened, etc., making a secure installation 
impossible and flatness cannot be surely installed and it 
causes the tube omission and the air leakage after it 
closes it. 

(2) Grasp the tube and push it in slowly, inserting it securely 

all the way into the fitting. 

(3) After inserting the tube, pull on it lightly to confirm that it 

will not come out. If it is not installed securely all the way 
into the fitting, this can cause problems such as air 
leakage or the tube pulling out. 

2) Detaching of tubing 

(1) Push in the release button sufficiently, and push the collar 

evenly at the same time.   

(2) Pull out the tube while holding down the release button so 

that it does not come out. If the release button is not 
pressed down sufficiently, there will be increased bite on 
the tube and it will become more difficult to pull it out. 

(3) When the removed tube is to be used again, cut off the 

portion which has been chewed before reusing it. If the 
chewed portion of the tube is used as is, this can cause 
trouble such as air leakage or difficulty in removing the 
tube. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Connect so that polarity is matched to the connector’s (+), (-) and 
A, B and COM indicators, In the case of voltage specifications 
other than 12 or 24 VDC, take care to avoid mistaking polarity, as 
there is no diode to prevent reverse current. 
In the event that lead wires are connected in advance, they will be 
as shown below. 
 

Pos. common specifications 

A    (-) : Black 
COM (+): Red 
B    (-) : White(Without lead wire case of single solenoid) 

 
Neg. common specifications 

A    (+) : Black 
COM (-): Yellow 

B   (+) : White(Without lead wire case of single solenoid)

 

 

Light Indication 

 

 

When equipped with light/surge voltage suppressor, the light 
window turns orange when solenoid A is energized, and it turns 
green when solenoid B is energized. 

 

 

 

 

 

 

 

 

 

 

 

 

Fixed DIN rail manifold 

 

 

Fixed "45", "45

" DIN rail manifold to the setting side with screws, 

fix points as follows:2 to 5 stations: 2 points 6 to 10 stations : 

3points 11 to 15 stations: 4 points 16 to 20 stations:5 points 

If fixed at lesser points than specified and use it, there could be a 

warp or torsion in the DIN rail and the manifold and lead to bring 

some troubles such as air leakage. 

 

 

 

 

Mount it so that there is no slippage or deformation in gaskets, 

and tighten with the tightening torque as shown below. 

   

Light/surge Voltage Suppressor   

Solenoid Valve Mounting 

Caution 

Model 

Thread size 

Tightening torque 

SX3000 

M2 

0.17 N

SX5000 

M3 

0.8 N

SX7000 

M4 

1.4 N

 

 

SX3000/5000/7000 Series 

Specific Product Precautions  3 

 

Be sure to read before handling.   

 

Caution 

 

 

Solenoid A 

 

A side: Orange(Right) 
B side: Green(Left) 

 

Indicator light 

Solenoid B 

Caution 

Caution 

 

- 11 - 

 

SX3000-OMM0002-B 

 

Summary of Contents for SX3000 Series

Page 1: ...Doc no SX3000 OMM0002 B PRODUCT NAME 5 Port Solenoid Valve MODEL Series Product Number SX3000 5000 7000 Series...

Page 2: ...Precautions on Design Selection 4 5 Mounting 6 Piping 6 Wiring 6 Lubrication 7 Air Supply 7 Operating Environment 7 Maintenance 8 Specific Product Precautions 9 to 11 Valve Construction 12 13 Troubles...

Page 3: ...e when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly oper...

Page 4: ...duct 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year...

Page 5: ...e In addition at the time of vacuum adsorption be sure to vacuum at all times Failure to do so may result in foreign matter sticking to the adsorption pad or air leakage causing the workpiece to drop...

Page 6: ...d state may switch over see Figure 1 When installing a breaker circuit for the loading power supply consider using a solenoid valve with polarity with polarity protection diode or install a surge abso...

Page 7: ...itable wrench to tighten the hexagonal portion of the body an additional 1 6 to 1 4 turn The reference value for the tightening torque is 1 to 1 5 N m Note Excessive tightening may damage the thread p...

Page 8: ...ll an air filter Install an air filter upstream near the valve Select an air filter with a filtration size of 5 or smaller 3 Take measures to ensure air quality such as by installing an aftercooler ai...

Page 9: ...o operate 3 Low frequency operation Valves should be operated at least once every 30 days to prevent malfunction Use caution regarding the air supply 4 Manual override When the manual override is oper...

Page 10: ...port valve is required How to Use Plug Connector When attaching and detaching a connector first shut off the electric power and the air supply Also crimp the lead wires and sockets securely 1 Attachi...

Page 11: ...ocket s hook with a stick having a thin tip approx 1 mm If the socket is used again spread the hook outward Common Connector Assembly Wiring When ordering common connector assemblies alone wiring shou...

Page 12: ...be used again cut off the portion which has been chewed before reusing it If the chewed portion of the tube is used as is this can cause trouble such as air leakage or difficulty in removing the tube...

Page 13: ...12 SX3000 OMM0002 B...

Page 14: ...13 SX3000 OMM0002 B...

Page 15: ...brasion spool ass y ring in the case of rubber seal Poor operation or adherence Excessive amount of lubricant Higher voltage or wrong coil used Faulty wiring Poor contact at contactor wire or connecti...

Page 16: ...cation was suspended temporary Water splashed directely Strong impact was given Alien substance such as drain and particle got into Drain or garbage invaded a valve Reduce the amount of lubricant to t...

Page 17: ...kyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 201...