background image

 

 

Design / Selection

 

 
 

1. Confirm the specifications. 

Products represented in this manual are designed only for use 

in compressed air systems (including vacuum). 

Do not operate at pressures or temperatures, etc., beyond the 

range of specifications, as this can cause damage or 
malfunction. (Refer to the specifications.) 

Please contact SMC when using a fluid other than compressed 

air (including vacuum). 

We do not guarantee against any damage if the product is used 

outside of the specification range. 

2. Actuator drive 

When an actuator, such as a cylinder, is to be driven using a 

valve, take appropriate measures (cover installation or approach 
prohibition) to prevent potential danger caused by actuator 
operation. 

3. Intermediate stops 

For 3-position closed center type, it is difficult to make a piston 

stop at the required position accurately due to the 
compressibility of air. 

Furthermore, since valves and cylinders are not guaranteed for 

zero air leakage, it may not be possible to hold a stopped 
position for an extended period of time. 

Please contact SMC if it is necessary to hold a stopped position 

for an extended period of time.

 

4. Effects of back pressure when using a manifold 

Use caution when valves are used on a manifold, because an 
actuator may malfunction due to back-pressure. 
Especially when using a 3-position exhaust center valve or 
single acting cylinder, take appropriate measures to prevent 
malfunction by using it with an individual EXH spacer assembly

 

or an individual exhaust manifold.

 

5. Holding pressure (including vacuum) 

Since the valves are subject to air leakage, they cannot be used 
for applications such as holding pressure (including vacuum) in 
a pressure vessel. 

6. Not suitable for use as an emergency shutoff valve, 

etc.

 

The valves listed in this manual are not designed for safety 
applications such as an emergency shutoff valve. If the valves 
are used for the mentioned applications, additional safety 
measures should be adopted.   

7. Release of residual pressure 

For maintenance and inspection purposes install a system for 
releasing residual pressure. Especially in the case of 3-position 
closed center valve type, ensure that the residual pressure 
between the valve and the cylinder is released. 

8. Operation in a vacuum condition 

When a valve is used for switching a vacuum, take measures to 
install a suction filter or similar to prevent external dust or other 
foreign matter from entering inside the valve. 
In addition, at the time of vacuum adsorption, be sure to vacuum 
at all times. Failure to do so may result in foreign matter sticking 
to the adsorption pad, or air leakage causing the workpiece to 
drop. 

 

 

 

9. Regarding a vacuum switch valve and a vacuum 

release valve 

If a non-vacuum valve is installed in the middle of piping system 
having a vacuum, the vacuum condition will not be maintained. 
Use a valve designed for use under vacuum conditions. 

10. Double solenoid type 

When using the double solenoid type for the first time, actuators 
may travel in an unexpected direction depending on the 
switching position of the valve. Implement measures to prevent 
any danger from occurring when operating the actuator. 

11. Ventilation 

Provide ventilation when using a valve in a confined area, such 
as in a closed control panel. For example, install a ventilation 
opening, etc. in order to prevent pressure from increasing inside 
of the confined area and to release the heat generated by the 
valve. 

12. Extended periods of continuous energization 

  - If a valve will be continuously energized for an extended period 

of time, the temperature of the valve will increase due to the 
heat generated by the coil assembly. This will likely adversely 
affect the performance of the valve and any nearby peripheral 
equipment. It is possible to shorten the energized time by 
making a valve with an N.O. (normally open) specification. 

 

- For applications such as mounting a valve on a control panel, 

incorporate measure to limit the heat radiation so that the 
temperature will be high when a 3 station manifold. 

13. Do not disassemble the product or make any 

modifications, including additional machining. 

Doing so may cause human injury and/or an accident. 

 

 

1. Precautions for 2-position double solenoid valves 

If a double solenoid valve is operated with momentary 
energization, it should be energized for at least 0.1 seconds. 
However, depending on the piping conditions, the cylinder may 
malfunction even when the double solenoid valve is energized 
for 0.1 seconds or longer. In this case, energize the double 
solenoid valve until the cylinder is exhausted completely. 

2. Leakage voltage

 

Take note that the leakage voltage will increase when a resistor 
is used in parallel with switching element or when a C-R circuit 
(surge voltage suppressor) is used for protecting a switching 
device because of the passing leakage voltage through the C-R 
circuit. The suppressor residual leakage voltage should be 3% 
or less of the rated voltage. 

 

Warning 

SX3000/5000/7000  Series   

Precautions for 5  Port Solenoid Valve  1 

 

 

Be sure to read before handling.

 

Caution 

 

- 4 - 

 

SX3000-OMM0002-B 

 

Summary of Contents for SX3000 Series

Page 1: ...Doc no SX3000 OMM0002 B PRODUCT NAME 5 Port Solenoid Valve MODEL Series Product Number SX3000 5000 7000 Series...

Page 2: ...Precautions on Design Selection 4 5 Mounting 6 Piping 6 Wiring 6 Lubrication 7 Air Supply 7 Operating Environment 7 Maintenance 8 Specific Product Precautions 9 to 11 Valve Construction 12 13 Troubles...

Page 3: ...e when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly oper...

Page 4: ...duct 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year...

Page 5: ...e In addition at the time of vacuum adsorption be sure to vacuum at all times Failure to do so may result in foreign matter sticking to the adsorption pad or air leakage causing the workpiece to drop...

Page 6: ...d state may switch over see Figure 1 When installing a breaker circuit for the loading power supply consider using a solenoid valve with polarity with polarity protection diode or install a surge abso...

Page 7: ...itable wrench to tighten the hexagonal portion of the body an additional 1 6 to 1 4 turn The reference value for the tightening torque is 1 to 1 5 N m Note Excessive tightening may damage the thread p...

Page 8: ...ll an air filter Install an air filter upstream near the valve Select an air filter with a filtration size of 5 or smaller 3 Take measures to ensure air quality such as by installing an aftercooler ai...

Page 9: ...o operate 3 Low frequency operation Valves should be operated at least once every 30 days to prevent malfunction Use caution regarding the air supply 4 Manual override When the manual override is oper...

Page 10: ...port valve is required How to Use Plug Connector When attaching and detaching a connector first shut off the electric power and the air supply Also crimp the lead wires and sockets securely 1 Attachi...

Page 11: ...ocket s hook with a stick having a thin tip approx 1 mm If the socket is used again spread the hook outward Common Connector Assembly Wiring When ordering common connector assemblies alone wiring shou...

Page 12: ...be used again cut off the portion which has been chewed before reusing it If the chewed portion of the tube is used as is this can cause trouble such as air leakage or difficulty in removing the tube...

Page 13: ...12 SX3000 OMM0002 B...

Page 14: ...13 SX3000 OMM0002 B...

Page 15: ...brasion spool ass y ring in the case of rubber seal Poor operation or adherence Excessive amount of lubricant Higher voltage or wrong coil used Faulty wiring Poor contact at contactor wire or connecti...

Page 16: ...cation was suspended temporary Water splashed directely Strong impact was given Alien substance such as drain and particle got into Drain or garbage invaded a valve Reduce the amount of lubricant to t...

Page 17: ...kyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 201...

Reviews: