11
Specifications
Each value of above represents at normal temperatures with fresh water.
Note) The discharge rates for PAP3310-P11, PAP3310S-
-
-
PAP3310-S11 are between 1 to 12 L/min.
Model
PA3310
PAP3310
Actuation
Automatically operated
Port size
Main fluid
suction
discharge port
Rc, NPT, G, NPTF 3/8"
Female thread
Rc, NPT, G, NPTF 3/8" Female thread
3/8", 1/2" Tube extension
With nut (size 3, 4, 5)
3/8", 1/2" Integrated fitting type
Pilot air
supply/exhaust
port
Rc, NPT, G, NPTF 1/4" Female thread
Material
Body wetted
areas
New PFA
Diaphragm
PTFE
Check valve
PTFE, New PFA
Discharge rate
1 to 13L/min
Note)
Average discharge pressure
0 to 0.4MPa
Pilot air pressure
0.2 to 0.5MPa
Air consumption
140 L/min (ANR) or less
Suction
lifting
range
Dry
0.5 m (Interior of pump dry)
Wet
Up to 4 m (liquid inside pump)
Noise
80 dB (A) or less (Option: with silencer, AN20)
Maximum
withstand
pressure
0.75MPa
Diaphragm life
50 million times
Fluid temperature
0 to 100°C (No freezing, heat cycle not applied)
Ambient temperature
0 to 100°C (No freezing, heat cycle not applied)
Maximum viscosity
1000mPa
・
s
Weight
2.1 kg (without foot)
Mounting orientation
Horizontal (with mounting foot at bottom)
Packaging
General environment
Clean double packaging