Piping and Operation 

 

Caution 

Mounting posture of the pump is set with the mounting foot facing downward. Air to be supplied to 
the air supply port <AIR SUP> should be cleaned and filtered through AF filter, etc. Air with foreign 
matter or drainage etc. will have negative effects on the built-in directional control valve and will lead 
to malfunction. When air needs additional purification, use a filter (AF series), and a mist separator 
(AM series) together. Maintain the proper tightening torque for fittings and mounting bolts, etc. 
Looseness can cause problems such as fluid and air leaks, while over tightening can cause damage 
to threads and parts, etc. 
 

  Starting and Stopping    Refer to circuit example (1) 

1. Connect air piping to the air supply port <AIR SUP> and connect piping for the fluid to be 

transfered to the suction port <FLUID IN> and the discharge port <FLUID OUT>. 

2. Using a regulator, set the pilot air pressure within the range of 0.2 to 0.5 MPa. Then, the pump 

operates when power is applied to the 3 port solenoid valve of the air supply port <AIR SUP>, the 
sound of exhaust begins from the air exhaust port <AIR EXH> and fluid flows from the suction 
port <FLUID IN> to the discharge port <FLUID OUT>. 

At this time, the throttle on the discharge side is in an open state. The pump performs suction with 
its own power even without priming. (Dry state suction lifting range: up to 0.5 m) To restrict 
exhaust noise, attach a silencer (AN20-02: option) to the air exhaust port <AIR EXH>. 

3. To stop the pump, exhaust the air pressure being supplied to the pump by the 3 port solenoid 

valve of the air supply port <AIR SUP>. The pump will also stop if the throttle on the discharge 
side is closed. 

 

  Discharge Flow Rate Adjustment   

1. To adjust the flow rate from the discharge port <FLUID OUT>, use the throttle connected to the 

discharge side. Refer to circuit example (1). Note that this product cannot be used as a fixed 
quantity liquid dispense pump. 

2. When operating with a discharge flow rate below the specification range, provide a by-pass circuit 

from the discharge side to the suction side to ensure the minimum flow rate inside the process 
pump. With a discharge flow rate below the minimum flow rate, the process pump may stop due 
to unstable operation. Refer to circuit example (2). (Minimum flow rates: 1 L/min) 

 
<Reset Button> 

When the pump stops during operation, press the reset button. This makes it possible to restore 
operation in case the switching valve be-comes clogged due to foreign matter in the supply air. 

 
<Air Operated Reset Port> 

It is possible to restore operation by supplying air to the air operated reset port without directly 
pressing the reset button, such as by remote control. Pressure equivalent to or greater than pilot 
air pressure (but less than 0.5 MPa) is required to reset air. Refer to air operated reset circuit 
example (3).   
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Circuit example (1) 

Circuit example (2) 

Process Pump 

Bypass 

Air 

supply 

Regulator 

3 port 

solenoid valve 

Air 

SUP 

Air 

EXH 

Silencer 

Transfer fluid 

FLUID 

OUT 

FLUID 

IN 

Process 

Pump 

Air filter 

Strainer 

Throttle 

Circuit example (3) 

3 port solenoid 
valve for remote 
reset 

Air supply 

PA(P)3310 
Air operated 
reset port 

Summary of Contents for PA3310 Series

Page 1: ...Doc no PAB OM E001 F PRODUCT NAME Process Pump MODEL Series Product Number PA P 3310 Series...

Page 2: ...ons P 2 to 3 Names and functions of parts P 4 Precautions P 5 to 9 Applicable Fluids P 10 Specifications P 11 Performance Curve P 12 to 13 Working Principle P 14 Maintenance Parts P 14 Piping and Oper...

Page 3: ...nt failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The asse...

Page 4: ...ts 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product...

Page 5: ...scharge piping Pilot air supply port AIR SUP Supplies air of set pressure Connect the air piping Pilot air exhaust port AIR EXH Exhausts pilot air Reset button Air operated reset port Resets the pump...

Page 6: ...wder If the specific gravity of the slurry is 3 or more use particles that have a diameter of no more than 0 15 mm and have been passed through a 100 or finer mesh e g iron powder Take countermeasures...

Page 7: ...type of some models adopts an air spring for the built in air control circuit and the pump may malfunction and stop when the pilot air pressure fluctuation exceeds 50 kPa 3 Reverse flow The check val...

Page 8: ...P2 to 3 of Best Pneumatics 6 Use of humid air may cause condensation inside the body Use air which has been treated by a refrigerated air dryer such as IDF series when condensation occurs When dew for...

Page 9: ...afety of the system before performing work Caution 1 Caution when transferring a highly penetrating liquid When transferring a liquid that is highly penetrating through fluoropolymer components of the...

Page 10: ...be sure to continue lubricating the pump Warning 1 Test before using with the actual equipment Test the pump before using it with the actual equipment Even if there is no problem in a short term test...

Page 11: ...applicability may vary depending on your operating conditions be sure to check it by means of experimentation 6 Compatibility is indicated for fluid temperatures specified for the respective products...

Page 12: ...areas New PFA Diaphragm PTFE Check valve PTFE New PFA Discharge rate 1 to 13L min Note Average discharge pressure 0 to 0 4MPa Pilot air pressure 0 2 to 0 5MPa Air consumption 140 L min ANR or less Suc...

Page 13: ...marked point In this case the point is between the discharge curves solid lines for SUP 0 4 MPa and SUP 0 5 MPa and based on the proportional relationship to these lines the pilot air pressure for th...

Page 14: ...e required specification example the viscosity is 100 mPa s and the discharge rate is 2 7 L min Since this is equivalent to 45 of the discharge rate for fresh water 2 7 L min 0 45 6 L min indicating t...

Page 15: ...opposite direction the fluid in pump chamber A is forced out and fluid is sucked into pump chamber B 3 Continuous suction and discharge is performed by the reciprocal motion of the diaphragm Maintenan...

Page 16: ...IR EXH 3 To stop the pump exhaust the air pressure being supplied to the pump by the 3 port solenoid valve of the air supply port AIR SUP The pump will also stop if the throttle on the discharge side...

Page 17: ...16 Dimensions Integrated fitting type With nut Tube extension...

Page 18: ...4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on...

Reviews: