background image

13 

 

 

Viscosity Characteristics 

(Flow rate correction for viscous fluids) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Selection from Viscosity Characteristic Graph 

Required specifications example: 
Find the pilot air pressure and pilot air consumption for a discharge rate of 2.7 L/min, and a viscosity 
of 100 mPa·s. 
 
Selection procedures: 
1. First find the ratio of the discharge rate for fresh water when viscosity is 100 mPa·s from the 

graph below. It is determined to be 45%. 

2. Next, in the required specification example, the viscosity is 100 mPa·s and the discharge rate is 

2.7 L/min. Since this is equivalent to 45% of the discharge rate for fresh water, 2.7 L/min ÷ 0.45 = 
6 L/min, indicating that a discharge rate of 6 L/min is required for fresh water. 

3. Finally, find the pilot air pressure and pilot air consumption based on selection from the flow 

characteristic graphs. 

 

Caution 

Viscosities up to 1000 mPa·s can be used. 
Viscosity and dynamic viscosity are obtained by the formulas below.   

Dynamic viscosity ν[m

2

/s]

 

Viscosity μ[Pa

s] 

Density ρ[kg/m

3

 
Formulas below can be used for common units 
- 1cP = 1mPa

s = 10

-3

Pa

- 1cSt = 1mm

2

/s = 10

-6

m

2

/s 

 

Summary of Contents for PA3310 Series

Page 1: ...Doc no PAB OM E001 F PRODUCT NAME Process Pump MODEL Series Product Number PA P 3310 Series...

Page 2: ...ons P 2 to 3 Names and functions of parts P 4 Precautions P 5 to 9 Applicable Fluids P 10 Specifications P 11 Performance Curve P 12 to 13 Working Principle P 14 Maintenance Parts P 14 Piping and Oper...

Page 3: ...nt failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The asse...

Page 4: ...ts 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product...

Page 5: ...scharge piping Pilot air supply port AIR SUP Supplies air of set pressure Connect the air piping Pilot air exhaust port AIR EXH Exhausts pilot air Reset button Air operated reset port Resets the pump...

Page 6: ...wder If the specific gravity of the slurry is 3 or more use particles that have a diameter of no more than 0 15 mm and have been passed through a 100 or finer mesh e g iron powder Take countermeasures...

Page 7: ...type of some models adopts an air spring for the built in air control circuit and the pump may malfunction and stop when the pilot air pressure fluctuation exceeds 50 kPa 3 Reverse flow The check val...

Page 8: ...P2 to 3 of Best Pneumatics 6 Use of humid air may cause condensation inside the body Use air which has been treated by a refrigerated air dryer such as IDF series when condensation occurs When dew for...

Page 9: ...afety of the system before performing work Caution 1 Caution when transferring a highly penetrating liquid When transferring a liquid that is highly penetrating through fluoropolymer components of the...

Page 10: ...be sure to continue lubricating the pump Warning 1 Test before using with the actual equipment Test the pump before using it with the actual equipment Even if there is no problem in a short term test...

Page 11: ...applicability may vary depending on your operating conditions be sure to check it by means of experimentation 6 Compatibility is indicated for fluid temperatures specified for the respective products...

Page 12: ...areas New PFA Diaphragm PTFE Check valve PTFE New PFA Discharge rate 1 to 13L min Note Average discharge pressure 0 to 0 4MPa Pilot air pressure 0 2 to 0 5MPa Air consumption 140 L min ANR or less Suc...

Page 13: ...marked point In this case the point is between the discharge curves solid lines for SUP 0 4 MPa and SUP 0 5 MPa and based on the proportional relationship to these lines the pilot air pressure for th...

Page 14: ...e required specification example the viscosity is 100 mPa s and the discharge rate is 2 7 L min Since this is equivalent to 45 of the discharge rate for fresh water 2 7 L min 0 45 6 L min indicating t...

Page 15: ...opposite direction the fluid in pump chamber A is forced out and fluid is sucked into pump chamber B 3 Continuous suction and discharge is performed by the reciprocal motion of the diaphragm Maintenan...

Page 16: ...IR EXH 3 To stop the pump exhaust the air pressure being supplied to the pump by the 3 port solenoid valve of the air supply port AIR SUP The pump will also stop if the throttle on the discharge side...

Page 17: ...16 Dimensions Integrated fitting type With nut Tube extension...

Page 18: ...4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on...