![background image](http://html1.mh-extra.com/html/smc-networks/mxqr-6/mxqr-6_operation-manual_1299195019.webp)
19
4-4 Fixing of body and guide
(1) Remove the locking adhesive from the fixing bolts and
clean them thoroughly. Apply locking adhesive at the
end of the screw. For the curing time, refer to the
catalog of the adhesive used, and take this into
consideration when mounting the product on the
machine.
The procedure for cleaning the fixing bolt is as follows.
1) Remove the residue of locking adhesive on the
removed bolt using an organic solvent. If
necessary, use a brush to physically peel and
clean off the residue more effectively.
2) Remove the locking adhesive from the female
thread in the same way.
Be careful to prevent the locking adhesive and
dust from entering the sliding part.
Do not wipe the grease off the guide.
3) Since organic solvent can be dangerous, refer to
its MSDS and take appropriate measures for safe
use.
(2) As shown in the figure on the right, push the body down to the reference mounting
surface at the port side or auto switch mounting side (Table 1) and tighten it
temporarily with the fixing bolts using a hexagon wrench. Then, tighten to the torque
specified in Table 2 using a torque wrench or torque driver.
The reference mounting surface has thin
slits on the table side.
Table 1 Pushing force (referential value)
Bore size (mm)
Pushing force N
6
3 to 6
8
5 to 10
12
10 to 20
16
20 to 40
20
30 to 60
25
45 to 90
Enlarged sectional view of adjuster
mounted on the left
Table
Guide block
Push
Reference mounting surface
Body
Adjuster mounted on the left (MXQR**L type)
Body
Port side
Reference mounting surface (with thin slit)
Fixing bolt
Push
Torque wrench
Push
Referential mounting surface (with thin slit)
Adjuster mounted on the right (MXQR** type)
Auto switch mounting groove
Body
Fixing bolt
Torque wrench